Barksdale Meets Technical Milestones for Phase II Earn-In and Updates SUN26-013R Assay Result of 65.5 Metres of 0.47% Cu and 1.24 g/t Ag, Including 7.6 Metres of 1.93% Cu and 1.96 g/t Ag - Seite 2
The Copper mineralization reported here is hosted in sericitic to advanced argillic-altered quartz monzonite to monzonite porphyry. Alteration is pervasive and intense, consisting mainly of sericite and quartz, overprinted by pyrophyllite, quartz, barite, and locally by later epithermal silicification with quartz veins and veinlets. This alteration assemblage places the mineralized zone within the upper portion of a porphyry-style mineral deposit.
In summary, results received to date, combined with historical data, indicate that the high-grade hypogene copper mineralization, occurring as primary copper sulfides, is part of a porphyry copper system with no apparent supergene enrichment zone or blanket. The results reported here further define a broad, low-grade chalcocite zone surrounding the porphyry and suggest that the high-grade sulfide veins represent the upper expression of deeper Cu-Mo porphyry-style mineralization.
Sampling and QAQC
Reverse circulation chip samples are placed in bar coded samples bags at the drill rig; samples averaging 5kgs are collected from the drill site by Barksdale representatives and transported to a locked, gated compound where they are dried prior to shipping. Dried samples are then placed in large totes and transferred to a Skyline Assayers truck for transport to the assay laboratory in Tucson Arizona. All samples for this drill program are being submitted for multi-element and gold analysis at Skyline Assayers & Laboratories of Tucson, Arizona. Samples are primary crushed to >75% passing -10 mesh (2000 microns) and then pulverized to >95% passing -150 mesh (100 microns). Gold is then analyzed by fire assay AAS using a 30g charge. Multi-element analysis was conducted using Aqua Regia digestion with ICP-OES analysis for 31 elements. All pulps and coarse rejects will be retained and returned to the Company for long-term storage.
Quality assurance & Quality Control (QAQC) samples were inserted into the sample stream at a 6% overall ratio comprising 2% certified reference materials or standards, 2% blank material, and 2% field duplicates that are collected at the drill. Results from the QAQC program are reviewed by the Qualified Person (QP) for the Company to assure assay result accuracy and precision prior to any data being released to the market.
Scientific and technical information in this news release has been reviewed and approved by Alan Roberts, Vice President of Exploration of the Company, a Certified Professional Geologist (CPG) with the American Institute of Professional Geologist (AIPG # 11260) and is a "Qualified Person" as defined in National Instrument 43-101.

