    Okayama University Research  996  0 Kommentare Measuring ion Concentration in Solutions for Clinical and Environmental Research - Seite 2

    Thinking about the future directions the team is interested to explore, the author says that "we will attempt the integration for multi-ion sensing and reducing the laser spot size to improve the accuracy of THz chemical microscopy."

    About Okayama University 

    Okayama University is one of the largest comprehensive universities in Japan with roots going back to the Medical Training Place sponsored by the Lord of Okayama and established in 1870. Now with 1,300 faculty and 13,000 students, the University offers courses in specialties ranging from medicine and pharmacy to humanities and physical sciences.

    Okayama University is located in the heart of Japan approximately 3 hours west of Tokyo by Shinkansen.

    Website: http://www.okayama-u.ac.jp/index_e.html

    Correspondence to 

    Associate Professor Toshihiko Kiwa, Ph.D.

    Advanced Electro Measurement Technology Laboratory,

    Graduate School of Interdisciplinary Science and Engineering

    in Health Systems, Okayama University,

    3-1-1 Tsushimanaka, Kita-Ku, Okayama 700-8530, Japan

    kiwa@okayama-u.ac.jp

    http://www.ec.okayama-u.ac.jp/~sense/index.html

    Further information
    Okayama University
    1-1-1 Tsushima-naka , Kita-ku , Okayama 700-8530, Japan
    Public Relations and Information Strategy
    E-mail: www-adm@adm.okayama-u.ac.jp

    Website: http://www.okayama-u.ac.jp/index_e.html
    Okayama Univ. e-Bulletin: http://www.okayama-u.ac.jp/user/kouhou/ebulletin/
    About Okayama University (YouTube): https://www.youtube.com/watch?v=iDL1coqPRYI
    Okayama University Image Movie (YouTube): https://www.youtube.com/watch?v=KU3hOIXS5kk

    Reference
     

    Toshihiko Kiwa, Tatsuki Kamiya, Taiga Morimoto, Kenji Sakai, And Keiji Tsukada. pH measurements in 16-nL-volume solutions using terahertz chemical microscopy. Optics Express, 26(7), 8232-8238, 2018.

    DOI: https://doi.org/10.1364/OE.26.008232

    https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-26-7-8232&id=383910

    Reference (Okayama Univ. e-Bulletin): Associate Professor Kiwa's team 

    e-Bulletin Vol.4:Unique terahertz chemical microscope for mapping chemical reactions

    e-Bulletin Vol.10:Simple, compact, highly sensitive SQUID based magnetic field measurement sysytem to detection of a very small magnetic signals

    e-Bulletin Vol.11:High-performance Terahertz Project kick-off symposium

    e-Bulletin Vol.13:Terahertz chemical microscope: Innovative terahertz technology for high resolution mapping of chemical reactions, label free immunoassays, cosmetics research, and more.

    Seite 2 von 2



    PR Newswire (engl.)
    0 Follower
    Autor folgen
    Verfasst von PR Newswire (engl.)
    Okayama University Research Measuring ion Concentration in Solutions for Clinical and Environmental Research - Seite 2 OKAYAMA, Japan, June 27, 2018 /PRNewswire/ - Okayama University researchers describe in the journal Optics Express the use of Terahertz (THz) chemical microscopy to measure the pH of water-based solutions with a volume as small as 16 nL. The …

    Schreibe Deinen Kommentar

    Disclaimer