checkAd

     209  0 Kommentare Orchestra BioMed Demonstrates Strength of Cardiovascular Pipeline with Virtue SAB and AVIM Therapy Presentations at CRT 2024 Annual Meeting

    • New pharmacokinetic data demonstrate Virtue SAB enables extended release of sirolimus above required tissue concentrations in target arterial sites without polymer degradation or detectable remaining polymer within 90 days of balloon delivery
    • AVIM therapy presentation highlighted recent clinical results showing favorable hemodynamic effects and long-term reduction in 24-hour ambulatory systolic blood pressure, as well as the design of the BACKBEAT global pivotal study now enrolling in collaboration with Medtronic, plc (NYSE:MDT)

    NEW HOPE, Pa., March 13, 2024 (GLOBE NEWSWIRE) -- Orchestra BioMed Holdings, Inc. (Nasdaq: OBIO, “Orchestra BioMed” or the “Company”), a biomedical company accelerating high-impact technologies to patients through risk-reward sharing partnerships, today announced two oral presentations were given at the Cardiovascular Research Technologies (“CRT”) 2024 Meeting in Washington, D.C. One presentation featured new preclinical pharmacokinetic (“PK”) data on Virtue Sirolimus AngioInfusion Balloon (“SAB”), a novel drug-eluting balloon angioplasty system designed to deliver a proprietary, extended-release formulation of sirolimus, SirolimusEFR to the vessel wall during balloon angioplasty without any coating on the balloon surface. A second presentation featured recently reported clinical data on atrioventricular interval modulation (“AVIM”) therapy (also known as BackBeat CNT), an investigational therapy delivered via standard dual-chamber pacemakers designed to immediately, substantially and persistently lower blood pressure. The AVIM presentation also outlined the design of the currently enrolling BACKBEAT global pivotal study evaluating AVIM therapy in hypertensive pacemaker patients in collaboration with Medtronic.

    Virtue SAB Oral Presentation, presented by Dean Kereiakes, M.D., President and Medical Director of The Christ Hospital Heart and Vascular Institute and Professor of Clinical Medicine at The Ohio State University

    Dr. Kereiakes’ presentation, focused on the role of drug-coated and drug-eluting balloon angioplasty systems for the treatment of coronary in-stent restenosis (“ISR”), outlined key points of differentiation and potential advantages for Virtue SAB, including:

    • No surface drug coating and, therefore, no drug loss in-transit to a target arterial lesion or creation of large particulates during balloon inflation
    • Focal uptake and extended release of sirolimus at tissue concentrations greater than the 1 ng/mg tissue concentration known to be required for effective control of cellular proliferation through the critical healing period.
      • Supported by published preclinical data of over 750 coronary artery balloon treatments
    • New preclinical PK data demonstrating that SostenocelTM, the proprietary polymer system enabling Virtue SAB’s SirolimusEFR, was shown to be eliminated in SirolimusEFR-treated stented arteries without detectable degradation, which can lead to localized tissue inflammation. Specifically, the presented PK data showed that:
      • Sostenocel was undetectable at 90 days in treated arteries and at 3 days in all non-target tissues
      • Molecular weight of Sostenocel remained unchanged prior to elimination, showing no evidence of in-vivo degradation.

    Lesen Sie auch

    “Virtue SAB represents a therapeutic innovation that may provide a reliable method to deliver the proven benefits of sirolimus, the gold standard therapeutic used in drug-eluting stents, during balloon angioplasty for the treatment of coronary in-stent restenosis without the potential risks associated with a permanent metal implant or a balloon surface coating,” commented Dr. Kereiakes. “Realizing the advantages of sirolimus requires a novel solution that enables sufficient drug uptake and extended drug release at necessary tissue concentrations through the 30-day critical healing period post-procedure. The preclinical data presented at CRT demonstrate how the Sostenocel polymer system that enables SirolimusEFR, the proprietary drug formulation used in Virtue SAB, is eliminated prior to degradation, enabling the long-term pharmacokinetics to support sirolimus arterial tissue concentrations that are essential for effective prevention of restenosis without the inflammatory risks associated with polymer degradation.”

    Seite 1 von 4



    globenewswire
    0 Follower
    Autor folgen

    Verfasst von globenewswire
    Orchestra BioMed Demonstrates Strength of Cardiovascular Pipeline with Virtue SAB and AVIM Therapy Presentations at CRT 2024 Annual Meeting New pharmacokinetic data demonstrate Virtue SAB enables extended release of sirolimus above required tissue concentrations in target arterial sites without polymer degradation or detectable remaining polymer within 90 days of balloon deliveryAVIM …